Modules with high temperature difference
Product notation |
Input current through a thermoelectric cooler resulting in greatest DT (DTmax) |
Maximum cooling power at Tamb=27°C |
Voltage on a thermoelectric cooler contacts at dTmax |
Maximum achievable temperature difference between the hot and cold side of a thermoelectric cooler |
Electric resistance of a thermoelectric cooler measured at an alternating current with the frequency of 1 kHz |
Width of the side A |
Width of the side B |
Width of the side C |
The diameter of the module |
Module height |
Status |
Ordet the product |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FROST-72 | 6.2 | 62.0 | 16.3 | 72 | 2.1 | 40.0 | 40.0 | 40.0 | 40.0 | 3.9 | Available | Buy |
Compare
|
FROST-74 | 6.3 | 65.0 | 16.7 | 74 | 2.1 | 40.0 | 40.0 | 40.0 | 40.0 | 3.9 | Available | Buy |
Compare
|
FROST-75 | 6.3 | 66.0 | 16.8 | 75 | 2.1 | 40.0 | 40.0 | 40.0 | 40.0 | 3.9 | For order | Buy |
Compare
|
ICE-71 | 8.0 | 80.0 | 16.1 | 71 | 1.5 | 40.0 | 40.0 | 40.0 | 40.0 | 3.4 | Available | Buy |
Compare
|
Product notation |
Input current through a thermoelectric cooler resulting in greatest DT (DTmax) |
Maximum cooling power at Tamb=27°C |
Voltage on a thermoelectric cooler contacts at dTmax |
Maximum achievable temperature difference between the hot and cold side of a thermoelectric cooler |
Electric resistance of a thermoelectric cooler measured at an alternating current with the frequency of 1 kHz |
Width of the side A |
Width of the side B |
Width of the side C |
The diameter of the module |
Module height |
Status |
Ordet the product |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TB-2-(59-18)-1,2 | 1.3 | 2.2 | 7.1 | 93 | 5.3 | 12.0 | 12.0 | 6.0 | 6.0 | 6.1 | For order | Buy |
Compare
|
TB-2-(127-127)-1,3 | 2.8 | 16.1 | 15.4 | 83 | 4.7 | 30.0 | 30.0 | 30.0 | 30.0 | 8.8 | For order | Buy |
Compare
|
TB-2-(127-127)-1,15 | 5.8 | 34.0 | 15.4 | 84 | 2.3 | 40.0 | 40.0 | 40.0 | 40.0 | 8.5 | Available | Buy |
Compare
|
TB-2-(199-199)-0,8 | 10.2 | 95.0 | 24.0 | 84 | 2.3 | 40.0 | 40.0 | 40.0 | 40.0 | 6.8 | For order | Buy |
Compare
|
Product notation |
Input current through a thermoelectric cooler resulting in greatest DT (DTmax) |
Maximum cooling power at Tamb=27°C |
Voltage on a thermoelectric cooler contacts at dTmax |
Maximum achievable temperature difference between the hot and cold side of a thermoelectric cooler |
Electric resistance of a thermoelectric cooler measured at an alternating current with the frequency of 1 kHz |
Width of the side A |
Width of the side B |
Width of the side C |
The diameter of the module |
Module height |
Status |
Ordet the product |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TB-3-(49-17-4)-2,5 | 6.3 | 3.3 | 5.3 | 113 | 0.9 | 36.0 | 36.0 | 14.0 | 8.0 | 16.8 | For order | Buy |
Compare
|
Product notation |
Input current through a thermoelectric cooler resulting in greatest DT (DTmax) |
Maximum cooling power at Tamb=27°C |
Voltage on a thermoelectric cooler contacts at dTmax |
Maximum achievable temperature difference between the hot and cold side of a thermoelectric cooler |
Electric resistance of a thermoelectric cooler measured at an alternating current with the frequency of 1 kHz |
Width of the side A |
Width of the side B |
Width of the side C |
The diameter of the module |
Module height |
Status |
Ordet the product |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TB-4-(59-31-11-4)-1,5 | 0.8 | 0.4 | 6.9 | 118 | 8.9 | 12.0 | 12.0 | 4.0 | 2.0 | 12.2 | Available | Buy |
Compare
|