Online orders
Product notation |
Input current through a thermoelectric cooler resulting in greatest DT (DTmax) |
Maximum cooling power at Tamb=27°C |
Voltage on a thermoelectric cooler contacts at dTmax |
Maximum achievable temperature difference between the hot and cold side of a thermoelectric cooler |
Electric resistance of a thermoelectric cooler measured at an alternating current with the frequency of 1 kHz |
Width of the side A |
Width of the side B |
Width of the side C |
The diameter of the module |
Module height |
Status |
Ordet the product |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TB-63-1,4-1,5 | 6.1 | 29.7 | 7.9 | 70 | 1.1 | 20.0 | 40.0 | 20.0 | 40.0 | 4.0 | Available | Buy |
Compare
|
TB-127-1,4-1,5 | 6.1 | 60.0 | 15.9 | 70 | 2.1 | 40.0 | 40.0 | 40.0 | 40.0 | 3.9 | Available | Buy |
Compare
|
TB-63-1,4-1,15 | 7.9 | 37.9 | 7.8 | 69 | 0.7 | 40.0 | 20.0 | 40.0 | 20.0 | 3.6 | Available | Buy |
Compare
|
Product notation |
Input current through a thermoelectric cooler resulting in greatest DT (DTmax) |
Maximum cooling power at Tamb=27°C |
Voltage on a thermoelectric cooler contacts at dTmax |
Maximum achievable temperature difference between the hot and cold side of a thermoelectric cooler |
Electric resistance of a thermoelectric cooler measured at an alternating current with the frequency of 1 kHz |
Width of the side A |
Width of the side B |
Width of the side C |
The diameter of the module |
Module height |
Status |
Ordet the product |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
STORM | 3.6 | 36.0 | 16.1 | 70 | 3.2 | 40.0 | 40.0 | 40.0 | 40.0 | 3.6 | Available | Buy |
Compare
|
FROST-72 | 6.2 | 62.0 | 16.3 | 72 | 2.1 | 40.0 | 40.0 | 40.0 | 40.0 | 3.9 | Available | Buy |
Compare
|
DRIFT-1,15 | 7.9 | 120.0 | 24.6 | 69 | 2.4 | 40.0 | 40.0 | 40.0 | 40.0 | 3.6 | For order | Buy |
Compare
|
DRIFT-1,05 | 8.6 | 131.0 | 24.6 | 69 | 2.2 | 40.0 | 40.0 | 40.0 | 40.0 | 3.5 | Available | Buy |
Compare
|
DRIFT-0,8 | 11.3 | 172.0 | 24.6 | 69 | 1.7 | 40.0 | 40.0 | 40.0 | 40.0 | 3.2 | Available | Buy |
Compare
|
DRIFT-0,8 HT(200) L3 C | 11.8 | 191.0 | 25.9 | 74 | 1.6 | 40.0 | 40.0 | 44.0 | 40.0 | 3.2 | For order | Buy |
Compare
|
Product notation |
Input current through a thermoelectric cooler resulting in greatest DT (DTmax) |
Maximum cooling power at Tamb=27°C |
Voltage on a thermoelectric cooler contacts at dTmax |
Maximum achievable temperature difference between the hot and cold side of a thermoelectric cooler |
Electric resistance of a thermoelectric cooler measured at an alternating current with the frequency of 1 kHz |
Width of the side A |
Width of the side B |
Width of the side C |
The diameter of the module |
Module height |
Status |
Ordet the product |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TB-8-0,45-1,3 | 0.7 | 0.4 | 1.0 | 67 | 1.2 | 3.4 | 3.4 | 5.0 | 3.4 | 2.3 | Available | Buy |
Compare
|
TB-17-0,6-1,0 | 1.7 | 2.2 | 2.1 | 69 | 1.0 | 6.3 | 6.3 | 6.3 | 6.3 | 2.8 | Available | Buy |
Compare
|
TB-35-0,6-1,0 | 1.7 | 4.4 | 4.3 | 69 | 2.1 | 6.0 | 12.0 | 6.0 | 12.0 | 2.8 | Available | Buy |
Compare
|
TB-7-0,6-0,8 | 2.1 | 1.1 | 0.9 | 68 | 0.3 | 4.3 | 4.3 | 4.3 | 4.3 | 2.6 | For order | Buy |
Compare
|
TB-31-0,6-0,8 | 2.1 | 4.8 | 3.8 | 68 | 1.4 | 8.0 | 8.0 | 8.0 | 8.0 | 2.6 | Available | Buy |
Compare
|
Product notation |
Input current through a thermoelectric cooler resulting in greatest DT (DTmax) |
Maximum cooling power at Tamb=27°C |
Voltage on a thermoelectric cooler contacts at dTmax |
Maximum achievable temperature difference between the hot and cold side of a thermoelectric cooler |
Electric resistance of a thermoelectric cooler measured at an alternating current with the frequency of 1 kHz |
Width of the side A |
Width of the side B |
Width of the side C |
The diameter of the module |
Module height |
Status |
Ordet the product |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TB-2-(59-18)-1,2 | 1.3 | 2.2 | 7.1 | 93 | 5.3 | 12.0 | 12.0 | 6.0 | 6.0 | 6.1 | For order | Buy |
Compare
|
TB-2-(127-127)-1,3 | 2.8 | 16.1 | 15.4 | 83 | 4.7 | 30.0 | 30.0 | 30.0 | 30.0 | 8.8 | For order | Buy |
Compare
|
TB-2-(127-127)-1,15 | 5.8 | 34.0 | 15.4 | 84 | 2.3 | 40.0 | 40.0 | 40.0 | 40.0 | 8.5 | Available | Buy |
Compare
|
TB-2-(199-199)-0,8 | 10.2 | 95.0 | 24.0 | 84 | 2.3 | 40.0 | 40.0 | 40.0 | 40.0 | 6.8 | For order | Buy |
Compare
|
Product notation |
Input current through a thermoelectric cooler resulting in greatest DT (DTmax) |
Maximum cooling power at Tamb=27°C |
Voltage on a thermoelectric cooler contacts at dTmax |
Maximum achievable temperature difference between the hot and cold side of a thermoelectric cooler |
Electric resistance of a thermoelectric cooler measured at an alternating current with the frequency of 1 kHz |
Width of the side A |
Width of the side B |
Width of the side C |
The diameter of the module |
Module height |
Status |
Ordet the product |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TB-3-(49-17-4)-2,5 | 6.3 | 3.3 | 5.3 | 113 | 0.9 | 36.0 | 36.0 | 14.0 | 8.0 | 16.8 | For order | Buy |
Compare
|
Product notation |
Input current through a thermoelectric cooler resulting in greatest DT (DTmax) |
Maximum cooling power at Tamb=27°C |
Voltage on a thermoelectric cooler contacts at dTmax |
Maximum achievable temperature difference between the hot and cold side of a thermoelectric cooler |
Electric resistance of a thermoelectric cooler measured at an alternating current with the frequency of 1 kHz |
Width of the side A |
Width of the side B |
Width of the side C |
The diameter of the module |
Module height |
Status |
Ordet the product |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TB-4-(59-31-11-4)-1,5 | 0.8 | 0.4 | 6.9 | 118 | 8.9 | 12.0 | 12.0 | 4.0 | 2.0 | 12.2 | For order | Buy |
Compare
|