Ecogen's multistage thermoelectric cooling modules are used if a single-stage module cannot provide the required temperature difference of more than 70K. Ecogen has developed and serially produces multistage Peltier cooling modules with up to five stages. Each subsequent stage increases the temperature difference, but also increases the consumption of electrical power. This leads to a relative decrease in refrigeration capacity and efficiency with an increase in the number of cascades.
Multistage thermoelectric coolers
Terms and conditions of sale
Product notation |
Input current through a thermoelectric cooler resulting in greatest DT (DTmax) |
Maximum cooling power at Tamb=27°C |
Voltage on a thermoelectric cooler contacts at dTmax |
Maximum achievable temperature difference between the hot and cold side of a thermoelectric cooler |
Electric resistance of a thermoelectric cooler measured at an alternating current with the frequency of 1 kHz |
Width of the side A |
Width of the side B |
Width of the side C |
The diameter of the module |
Module height |
Status |
Ordet the product |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TB-2-(11-4)-1,5 | 1.0 | 0.4 | 1.3 | 93 | 1.3 | 6.0 | 4.0 | 2.0 | 4.0 | 6.7 | For order | Buy |
Compare
|
TB-2-(11-4)-1,2 | 1.2 | 0.5 | 1.3 | 92 | 1.6 | 6.0 | 4.0 | 2.0 | 4.0 | 6.1 | For order | Buy |
Compare
|
TB-2-(11-4)-1,0 | 1.5 | 0.6 | 1.3 | 92 | 0.9 | 6.0 | 4.0 | 2.0 | 4.0 | 5.7 | For order | Buy |
Compare
|
TB-2-(17-4)-1,5 | 1.1 | 0.4 | 2.0 | 94 | 1.9 | 6.0 | 8.0 | 4.0 | 2.0 | 6.7 | For order | Buy |
Compare
|
TB-2-(17-4)-1,2 | 1.3 | 0.5 | 2.0 | 93 | 1.5 | 6.0 | 8.0 | 4.0 | 2.0 | 6.1 | For order | Buy |
Compare
|
TB-2-(17-4)-1,0 | 1.6 | 0.6 | 2.0 | 91 | 1.3 | 6.0 | 8.0 | 4.0 | 2.0 | 5.7 | For order | Buy |
Compare
|
TB-2-(31-8)-1,5 | 1.1 | 0.9 | 3.6 | 93 | 3.4 | 8.0 | 10.0 | 4.0 | 4.0 | 6.7 | For order | Buy |
Compare
|
TB-2-(31-8)-1,2 | 1.3 | 1.1 | 3.6 | 92 | 2.7 | 8.0 | 10.0 | 4.0 | 4.0 | 6.1 | For order | Buy |
Compare
|
TB-2-(31-8)-1,0 | 1.6 | 1.3 | 3.6 | 91 | 2.3 | 8.0 | 10.0 | 4.0 | 4.0 | 5.7 | For order | Buy |
Compare
|
TB-2-(31-12)-1,5 | 1.0 | 1.1 | 3.7 | 93 | 3.6 | 8.0 | 10.0 | 6.0 | 4.0 | 6.7 | For order | Buy |
Compare
|
TB-2-(31-12)-1,2 | 1.2 | 1.4 | 3.7 | 92 | 2.9 | 8.0 | 10.0 | 6.0 | 4.0 | 6.1 | For order | Buy |
Compare
|
TB-2-(31-12)-1,0 | 1.4 | 1.6 | 3.7 | 91 | 2.4 | 8.0 | 10.0 | 6.0 | 4.0 | 5.7 | For order | Buy |
Compare
|
TB-2-(59-18)-1,5 | 1.1 | 1.8 | 7.1 | 94 | 6.7 | 12.0 | 12.0 | 6.0 | 6.0 | 6.7 | For order | Buy |
Compare
|
TB-2-(59-18)-1,2 | 1.3 | 2.2 | 7.1 | 93 | 5.3 | 12.0 | 12.0 | 6.0 | 6.0 | 6.1 | For order | Buy |
Compare
|
TB-2-(59-18)-1,0 | 1.5 | 2.6 | 7.0 | 92 | 4.4 | 12.0 | 12.0 | 6.0 | 6.0 | 5.7 | For order | Buy |
Compare
|
TB-2-(127-127)-1,3 | 2.8 | 16.1 | 15.4 | 83 | 4.7 | 30.0 | 30.0 | 30.0 | 30.0 | 8.8 | For order | Buy |
Compare
|
TB-2-(127-127)-1,15 | 5.8 | 34.0 | 15.4 | 84 | 2.3 | 40.0 | 40.0 | 40.0 | 40.0 | 8.5 | Available | Buy |
Compare
|
TB-2-(199-199)-0,8 | 10.2 | 95.0 | 24.0 | 84 | 2.3 | 40.0 | 40.0 | 40.0 | 40.0 | 6.8 | For order | Buy |
Compare
|
TB-2-(127-127)-1,15 (Bullfinch) | 8.8 | 31.0 | 8.9 | 87 | 1.1 | 40.0 | 40.0 | 40.0 | 40.0 | 7.5 | For order | Buy |
Compare
|
TB-2-(1-1)-1,8 | 67.7 | 1.8 | 0.1 | 89 | 0.0 | 6.1 | 12.2 | 2.3 | 5.6 | 4.1 | For order | Buy |
Compare
|
Product notation |
Input current through a thermoelectric cooler resulting in greatest DT (DTmax) |
Maximum cooling power at Tamb=27°C |
Voltage on a thermoelectric cooler contacts at dTmax |
Maximum achievable temperature difference between the hot and cold side of a thermoelectric cooler |
Electric resistance of a thermoelectric cooler measured at an alternating current with the frequency of 1 kHz |
Width of the side A |
Width of the side B |
Width of the side C |
The diameter of the module |
Module height |
Status |
Ordet the product |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TB-3-(31-11-4)-1,5 | 0.9 | 0.4 | 3.5 | 109 | 5.4 | 8.0 | 10.0 | 4.0 | 2.0 | 9.3 | For order | Buy |
Compare
|
TB-3-(31-11-4)-1,2 | 1.1 | 0.5 | 3.5 | 108 | 4.3 | 8.0 | 10.0 | 4.0 | 2.0 | 8.4 | For order | Buy |
Compare
|
TB-3-(31-11-4)-1,0 | 1.3 | 0.6 | 3.5 | 107 | 3.6 | 8.0 | 10.0 | 4.0 | 2.0 | 7.8 | For order | Buy |
Compare
|
TB-3-(49-17-4)-2,5 | 6.3 | 3.3 | 5.3 | 113 | 0.9 | 36.0 | 36.0 | 14.0 | 8.0 | 16.8 | For order | Buy |
Compare
|
TB-3-(59-17-4)-1,5 | 1.0 | 0.5 | 6.8 | 114 | 7.2 | 12.0 | 12.0 | 4.0 | 2.0 | 9.3 | For order | Buy |
Compare
|
TB-3-(59-17-4)-1,2 | 1.2 | 0.6 | 6.8 | 113 | 5.8 | 12.0 | 12.0 | 4.0 | 2.0 | 8.4 | For order | Buy |
Compare
|
TB-3-(59-17-4)-1,0 | 1.4 | 0.7 | 6.8 | 112 | 4.8 | 12.0 | 12.0 | 4.0 | 2.0 | 7.8 | For order | Buy |
Compare
|
TB-3-(83-18-4)-1,3 | 3.7 | 2.5 | 10.0 | 118 | 2.4 | 24.0 | 20.6 | 4.5 | 8.7 | 10.8 | For order | Buy |
Compare
|
Product notation |
Input current through a thermoelectric cooler resulting in greatest DT (DTmax) |
Maximum cooling power at Tamb=27°C |
Voltage on a thermoelectric cooler contacts at dTmax |
Maximum achievable temperature difference between the hot and cold side of a thermoelectric cooler |
Electric resistance of a thermoelectric cooler measured at an alternating current with the frequency of 1 kHz |
Width of the side A |
Width of the side B |
Width of the side C |
The diameter of the module |
Module height |
Status |
Ordet the product |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TB-4-(59-31-11-4)-1,5 | 0.8 | 0.4 | 6.9 | 118 | 8.9 | 12.0 | 12.0 | 4.0 | 2.0 | 12.2 | For order | Buy |
Compare
|
TB-4-(59-31-11-4)-1,2 | 1.0 | 0.5 | 6.9 | 117 | 7.2 | 12.0 | 12.0 | 4.0 | 2.0 | 11.0 | For order | Buy |
Compare
|
TB-4-(59-31-11-4)-1,0 | 1.1 | 0.6 | 6.9 | 116 | 6.0 | 12.0 | 12.0 | 4.0 | 2.0 | 10.2 | For order | Buy |
Compare
|
TB-4-(83-18-4-1)-1,3 | 3.7 | 0.8 | 10.0 | 138 | 2.4 | 24.0 | 20.6 | 2.4 | 4.5 | 13.6 | For order | Buy |
Compare
|
TB-4-(127-71-31-17)-1,65 | 6.8 | 14.8 | 14.1 | 107 | 2.1 | 48.0 | 48.0 | 22.0 | 22.0 | 15.0 | For order | Buy |
Compare
|
TB-4-(127-71-31-17)-1,5 | 3.0 | 6.8 | 15.5 | 111 | 5.3 | 40.0 | 40.0 | 15.0 | 15.0 | 13.7 | For order | Buy |
Compare
|
TB-4-(199-97-49-17)-1,5 | 6.7 | 16.9 | 23.6 | 111 | 3.5 | 62.0 | 62.0 | 20.0 | 20.0 | 14.5 | For order | Buy |
Compare
|
Product notation |
Input current through a thermoelectric cooler resulting in greatest DT (DTmax) |
Maximum cooling power at Tamb=27°C |
Voltage on a thermoelectric cooler contacts at dTmax |
Maximum achievable temperature difference between the hot and cold side of a thermoelectric cooler |
Electric resistance of a thermoelectric cooler measured at an alternating current with the frequency of 1 kHz |
Width of the side A |
Width of the side B |
Width of the side C |
The diameter of the module |
Module height |
Status |
Ordet the product |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TB-5-(198-95-43-20-10)-1.4-1.2 | 4.5 | 8.6 | 25.6 | 137 | 6.5 | 40.0 | 44.0 | 20.0 | 20.0 | 26.7 | For order | Buy |
Compare
|